Switching power supply 24V 120W 5A, DIN rail mountable, MEAN WELL, NDR-120-24
zoom_out_map
Switching power supply 24V 120W 5A, DIN rail mountable, MEAN WELL, NDR-120-24

Switching power supply 24V 120W 5A, DIN rail mountable, MEAN WELL, NDR-120-24

€ 48,90
Delivery is always on time  Delivery is always on time
Order product today by 12:00
And we will send your order today.
Time left:
11
:
00
:
00
Quantity

  • General
  • ModelNDR-120-24
  • DC Voltage24V
  • Rated Current5A
  • Current Range0 ~ 5A
  • Power120W
  • Voltage Adjustment Range24 ~ 28V
  • Ripple & Noise (max.)120mVp-p
  • Voltage Tolerance±1.0%
  • Line Regulation±0.5%
  • Load Regulation±1.0%
  • Setup and Rise Time1200ms, 60ms/230VAC; 2500ms, 60ms/115VAC at full load
  • Hold Up Time (typ.)16ms/230VAC; 10ms/115VAC at full load
  • Voltage Range90 ~ 264VAC; 127 ~ 370VDC (DC input operation possible by connecting AC/L(+), AC/N(-))
  • Frequency Range47 ~ 63Hz
  • Efficiency (typ.)88%
  • AC Current (typ.)2.25A/115VAC; 1.3A/230VAC
  • Inrush Current (typ.)20A/115VAC; 35A/230VAC
  • Leakage Current<1mA / 240VAC
  • Overload Protection105 ~ 130% rated output power (constant current limiting, recovers automatically after fault removal)
  • Over Voltage Protection29 ~ 33V (shut down output voltage, re-power on to recover)
  • Over Temperature ProtectionShut down output voltage, re-power on to recover
  • Withstand VoltageI/P-O/P: 3KVAC, I/P-FG: 2KVAC, O/P-FG: 0.5KVAC
  • Insulation ResistanceI/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25°C / 70% RH
  • Operating Temperature-20 ~ +70°C (Refer to Derating Curve)
  • Operating Humidity20 ~ 95% RH non-condensing
  • Storage Temperature and Humidity-40 ~ +85°C, 10 ~ 95% RH non-condensing
  • Temp. Coefficient±0.03%/°C (0 ~ 50°C)
  • Vibration10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Compliance to IEC60068-2-6
  • MTBF2636.8K hrs min. (Telcordia SR-332); 453.3K hrs min. (MIL-HDBK-217F at 25°C)
  • Dimensions40mm (W) x 125.2mm (H) x 113.5mm (D)
  • Weight0.6Kg; 20pcs/13Kg/1.02CUFT
  • CertificationsIEC62368-1, UL508, BS EN/EN62368-1, EAC TP TC 004, BS EN/EN60204-1
  • EMC EmissionBS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2, -3, EAC TP TC 020
  • EMC ImmunityEN61000-4-2,3,4,5,6,8,11, EN55035, EN61000-6-2 (EN50082-2), Heavy Industry Level
  • Operating AltitudeUp to 2000 meters
  • LED IndicatorDC OK
  • Cooling MethodFree air convection
  • MountingType DIN Rail TS35/7.5 or TS35/15