Legrand 411158 is a residual current circuit breaker with overcurrent protection (RCBO) designed for the safety of personnel and equipment. This 2-pole, 16A circuit breaker, featuring 30mA sensitivity, offers a 10kA nominal short-circuit breaking capacity, ensuring reliable circuit protection in the event of a fault. It is compatible with standard distribution boards and can be mounted using standard DIN rail systems, which allows for easy integration into electrical installations.



Specification

  • Type: Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
  • Number of Poles: 2P (protected poles: 2)
  • Rated Voltage: 230 V AC
  • Frequency: 50 Hz
  • Rated Current: 16 A (C tripping characteristic)
  • Rated Residual Current: 30 mA (AC residual current type)
  • Rated Short-Circuit Breaking Capacity (Icn according to EN 61009-1): 6 kA
  • Rated Short-Circuit Breaking Capacity (according to IEC 60947-2): 10 kA
  • Width: 4 modular spaces
  • Built-in Depth: 44 mm
  • Connection Terminals (rigid conductors): 1-35 mm²
  • Connection Terminals (flexible conductors): 1-25 mm²
  • Degree of Protection: IP20


Manufacturer

🔗 Manufacturer's Link


Documents / Certificates

🔗 Datasheet



Frequently Asked Questions (FAQ)

What is the difference between C characteristic and other tripping characteristics?

The C characteristic indicates that the circuit breaker will trip when the current reaches 5–10 times its rated current. This characteristic is suitable for general-purpose circuits, offering protection against both overloads and short circuits.

What is the purpose of this RCBO?

This residual current circuit breaker with overcurrent protection (RCBO) is designed to protect electrical circuits from overloads, short circuits, and dangerous residual currents, thereby ensuring the safety of both personnel and equipment.

In which networks can this RCBO be used?

This RCBO is designed for operation in 230V, 50Hz alternating current (AC) electrical networks. It meets low-voltage installation requirements and is suitable for various electrical distribution boards.

Similar items

arrow_upward