Salicru UPS SPS 500 ONE BL IEC is an uninterruptible power supply (UPS) designed to protect electronic equipment from power grid fluctuations and outages, ensuring a stable energy supply. This line-interactive technology model, with a power rating of 500VA/240W, is suitable for use in homes and small offices where efficient data protection and system operational continuity are essential. The tower format device with 4 IEC C13 outputs efficiently stabilizes voltage and provides backup power during critical situations.

Product Information

General Features

  • Model: SPS 500 ONE BL IEC
  • Manufacturer Code: 662AG000002
  • Technology: Line-interactive
  • Format: Tower
  • Power: 500VA / 240W

Input Characteristics

  • Input Voltage: 220 V / 230 V / 240 V AC
  • Voltage Range: 162 V ÷ 290 V
  • Stabilizer: AVR Buck / Boost
  • Nominal Frequency: 50 / 60 Hz (Auto sensing)
  • Protection: Thermal reset or fuse (depending on the model)

Output Characteristics

  • Output Voltage: 220 V / 230 V / 240 V AC
  • Voltage Accuracy (Battery Mode): ±10%
  • Waveform (Battery Mode): Simulated sine wave
  • Frequency: 50 / 60 Hz ± 1 Hz
  • Transfer Time: 2 / 6 ms
  • Socket Type: 4 x IEC

Batteries

  • Battery Type: Sealed Pb-Ca, maintenance-free, 3-5 years service life
  • Batteries: 1×12V/4.5Ah
  • Recharge Time: 4-6 hours to 90% capacity
  • User Replaceable Battery: Yes
  • Backup Runtime: Up to 20 minutes
  • Battery Replacement Signal: Yes

Communication and Management

  • Communication: USB HID
  • Monitoring Software: Compatible with Windows, Linux, Unix, Mac (downloadable from support.salicru.com)
  • Indicators: LEDs for Normal, AVR, and Battery Modes
  • Audible Alarms: Battery operation (every 10s), Low battery (every 1s), Overload (every 0.5s), Fault (continuous), Battery replacement (every 2s)
  • Functions: Cold start (power-on from battery), Automatic restart after backup power depletion

Environmental and Physical Data

  • Operating Conditions (Temperature): 0º C ÷ +40º C
  • Relative Humidity: Up to 90%, non-condensing
  • Maximum Operating Altitude: 2,400 m above sea level
  • Acoustic Noise: < 40 dB at 1 meter distance
  • Dimensions: 300 × 101 × 142 mm
  • Weight: 3.5 kg
  • Casing: Plastic

Standards and Certifications

  • Standards: EN IEC 62040-1 (Safety), EN IEC 62040-2 (EMC), EN IEC 62040-3 (Performance)
  • Certifications: ISO 9001, ISO 14001, ISO 45001